The M890G digital multimeter is a great buy for the hobbyist, technician or auto mechanic. Measures DC Volts and AC Volts at 10Mohm input impedance, DC and AC current, resistance up to 20M ohm, capacitance up to 20uF, frequency up to 20KHz, and temperature all the way up to 1000°C.
Includes a dedicated transistor socket for NPN and PNP transistor testing, auto power off to save batteries, audible continuity and diode testing, and a big display. Comes with standard test leads and a temperature test probe (K type thermocouple).
The popular 890 multimeter family includes many models: M890B+, M890D, M890C+, M890F, M890G, DT-890G and many more, all using the robust ICL7106 2000 count IC.
Note: The following values can differ slightly from model to model; consult your user manual for your meter's technical specifications.
Input impedance: 10MΩ
| Range | Resolution | Accuracy |
|---|---|---|
| 200mV | 0.1mV | ± 0.5% of rdg ± -1 digit |
| 2V | 1mV | ± 0.5% of rdg ± 1 digit |
| 20V | 10mV | ± 0.5% of rdg ± 1 digit |
| 200V | 100mV | ± 0.5% of rdg ± 1 digit |
| 1000V | 1V | ± 0.8% of rdg ± 2 digits |
Input impedance: 10MΩ at all ranges.
Frequency Response: 40Hz - 200Hz (40Hz-100Hz for the 200V and 700V range).
Overload Protection:
- 200mV: max. 15 seconds at a voltage of 300V AC
- all other ranges: 750V AC or 1000V DC.
| Range | Resolution | Accuracy |
|---|---|---|
| 200 mV | 0.1mV | ± 1.2% of rdg ± 3 digits |
| 2V | 1 mV | ± 0.8% of rdg ± 3 digits |
| 20V | 10 mV | ± 0.8% of rdg ± 3 digits |
| 200V | 100 mV | ± 0.8% of rdg ± 3 digits |
| 700V | 1V | ± 1.2% of rdg ± 3 digits |
Overload protection: 0.2A / 250V fuse
The 20A range is unfused. Maximum input current: 20 A for 15 seconds.
| Range | Resolution | Accuracy |
|---|---|---|
| 2mA | 1µA | ± 0.8% of rdg ± 1 digit |
| 20mA | 10µA | ± 0.8% of rdg ± 1 digit |
| 200mA | 100µA | ±1.2% of rdg ± 1 digit |
| 20A | 10mA | ± 2.0% of rdg ± 5 digits |
Overload protection: 0.2A / 250V fuse
The 20A range is unfused. Maximum input current: 20 A for 15 seconds.
| Range | Resolution | Accuracy |
|---|---|---|
| 200mA | 100µA | ± 2.0% of rdg ± 3 digits |
| 20A | 10mA | ± 3.0% of rdg ± 7 digits |
Note: some models have a 20mA range with a resolution of 10 µA and ±1,2% ± 3 digits accuracy.
| Range | Resolution | Accuracy |
|---|---|---|
| 200Ω | 0,1Ω | ± 0.8% of rdg ± 3 digits |
| 2kΩ | 1Ω | ± 0.8% of rdg ± 1 digits |
| 20 kΩ | 10Ω | ± 0.8% of rdg ± 1 digits |
| 200 kΩ | 100Ω | ± 0.8% of rdg ± 1 digits |
| 2MΩ | 1kΩ | ± 0.8% of rdg ± 1 digits |
| 20MΩ | 10kΩ | ± 1% of rdg ± 2 digits |
| 200MΩ (a few models only) | 100 kΩ | ± 5% of rdg ± 10 digits |
| Range | Resolution | Accuracy |
|---|---|---|
| 2000pF | 1pF | ± 2.5% of rdg ± 5 digits |
| 20nF | 10pF | ± 2.5% of rdg ± 5 digits |
| 200nF | 100pF | ± 2.5% of rdg ± 5 digits |
| 2µF | 1nF | ± 2.5% of rdg ± 5 digits |
| 20µF | 10nF | ± 2.5% of rdg ± 5 digits |
| Range | Resolution | Accuracy |
|---|---|---|
| 20kHz | 10Hz | ± 1% of rdg ± 1 digits |
hFE range:0-1000
Ib: ~10µA
Uce: ~ 2,8V.
"K" type thermocouple
| Range | Resolution | Accuracy |
|---|---|---|
| -50°C - 400°C | 1°C | ± 0.75% of rdg ± 3 digits |
| 400°C-1000°C | 1°C | ± 1.5% of rdg ± 15 digits |
Diode test forward current: ~ 1mA.
Voltage: ~ 2.8V
The built-in buzzer will sound, if the resistance under test is less than about 30 ohms.